Substation Faults and Protection - John Tarilanyo Afa - Books - Grin Verlag - 9783656412335 - April 19, 2013
In case cover and title do not match, the title is correct

Substation Faults and Protection

Price
HK$ 154
excl. VAT

Ordered from remote warehouse

Expected to be ready for shipping Jul 30 - Aug 5
Get notified about new John Tarilanyo Afa releases
Add to your iMusic wish list

Not rated yet

Technical Report from the year 2011 in the subject Engineering - Power Engineering, grade: A, Atlantic International University (Niger Delta University), course: SFP 673, language: English, abstract: The purpose of this work is to establish the type of faults that may result when substations are sited in the region of the Niger Delta due to the prevailing climatic conditions. This will aimed at ensuring as far as possible a small probability of damage to substation insulations. For most transmission lines, relatively large numbers of yearly flashovers are permitted but such number of insulation damages is absolutely not allowed for substations. Flashover of insulation at substation means a short circuit on the busbar which even with the modern means of relay protection can cause most sever system damages. Substations unlike lines have very low probability of damage therefore a quantitative idea of the probability, the so called index of lightning resistance of a substation is used. It is equal to the calculated number of years during which a voltage dangerous for the substation installation does not occur. For modern high voltage substations, the index of lightning resistance is calculated as hundred or even as thousand years which is a proof of attempts made by designers to ensure the largest degree of lightning resistance of substation (Rao,2008, U. S Dept of Agri.2001, Martinez and Castro 2003). Substations must be protected from the direct lightning strokes and voltage waves travelling from the line as well as switching surges. In transmission lines the induced strokes (indirect strokes) due to lightning are important for 11kv lines only. For high voltage transmission lines (up to 220kv) the surges due direct lightning strokes determine the line insulations design. For extra high voltage (400kv and above) the severity of swiching surges is much more than that due to lightning (Gupta, 2008). Whether external or internal over voltage, for reliable operations of subst


24 pages

Media Books     Paperback Book   (Book with soft cover and glued back)
Released April 19, 2013
ISBN13 9783656412335
Publishers Grin Verlag
Pages 24
Dimensions 148 × 210 × 2 mm   ·   51 g
Language German  

More by John Tarilanyo Afa

Show all